Publications

Found 113 results
Filters: Editorial-innovations-mr-hardware-ultra-low-ultra-high-field-0 is   [Clear All Filters]
Conference Proceedings
Winkler SA, Stelzer A..  2007.  A Novel Hybrid Analysis Approach for Subharmonic Self-Oscillating Mixers Combining Volterra Series and Conversion Matrix Methods. Proc. 37th European Microwave Integrated Circuit Conference.
Bozzi M., Winkler SA, Wu K..  2009.  Novel Compact and Broadband Interconnects based on Ridge Substrate Integrated Waveguide. Proc. 2009 IEEE International Microwave Symposium.
Winkler SA, Stelzer A..  2006.  A Novel Balanced Third and Fourth Harmonic Self-Oscillating Mixer with High Conversion Gain. Proc. 36th European Microwave Conference.
Winkler SA, Stelzer A..  2006.  A Novel Balanced Third and Fourth Harmonic Self-Oscillating Mixer with High Conversion Gain. Proc. 9th European Wireless Technology Conference.
Motovilova E, Ching T, Vincent J, Tan ETsoon, Taracila V, Hashimoto M, Robb F, Sneag D, Winkler SAngela.  2023.  Multi-channel, Stretchable, Self-Tuning Coil Array Based on Liquid Metal Technology . ISMRM.
Winkler SA, Motovilova E, Gökyar S, Saniour I, Robb F, Chaudhari A.  2021.  MRSaiFE: towards the real-time prediction of tissue heating in MRI - a feasibility study. ISMRM Virtual Conference.
Winkler SA, Saniour I, Chaudhari A, Robb F, Vaughan. T.  2020.  MRSaiFE: Tissue Heating Prediction for MRI: a Feasibility Study. 2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC).
Stara R., Winkler SA, Watkins R.D, Retico A., Tosetti M., Rutt BK.  2014.  Modular And Versatile Multi-Row Transmit Array Based On A Novel Decoupled Coil Element. Proc. Int. Soc. Magn. Res..
Moghadam MC, Winkler SA.  2023.  Model Generalization in SAR Prediction by Extending the MRSaiFE Deep Learning Framework. The New Wave of AI in Healthcare.
Zeng X.-B., Winkler SA, Wu K., Ye Y., Liu T.-J., He J.-M..  2009.  Measurement and Modeling of LNA Based on Load-Pull System. National Conference on Microwave and Millimeter-Waves (NCMMW).
Winkler SAngela, Stockmann JP, Warr P.A, Keil B., Watkins R., Wald L.L, Rutt B.K.  2015.  Magna Cum Laude Merit Award, Oral: Comparison of new element designs for combined RF-Shim arrays at 7T. ISMRM. :0860.
Gökyar S, Saniour I, Robb FJL, Nghiem A, Kainz W, Chaudhari A, Winkler SAngela.  2022.  MAGNA CUM LAUDE Merit Award | MRSaiFE: towards the real-time prediction of SAR in 3T and 7T MR RF coils - a feasibility studywith 10 body models. ISMRM.
Saniour I, Robb FJL, Taracila V, Vincent J, Voss HU, Kaplitt MG, J. Chazen L, Winkler SA.  2021.  Low-profile, flexible, and acoustically transparent receive-only MRI coil array for high sensitivity MR-guided focused ultrasound. Austrian Research & Innovation Talk (ARIT). Top 10 finalists
Winkler SA, Alejski A., Wade T., McKenzie C., Rutt BK.  2015.  Lorentz Damping and the Field Dependence of Gradient Coil Vibroacoustics. Proc. Int. Soc. Magn. Res..
Gökyar S, Voss HU, Taracila V, Robb FJL, Ballon DJ, Winkler SAngela.  2022.  In-silico shimming performance of a bore-sized 2-D UHF volume coil for different anatomies at 7T. ISMRM.
Saniour I, Robb FJL, Taracila V, Shin J, Mishra V, Fukuda R, Vincent J, Voss HU, Kaplitt MG, Chazen J.L. et al..  2022.  Improving image quality and acoustic transparency in MRgFUS at 3T using a low-profile, flexible receive coil array. ISMRM.
Hossain S, Taracila V, Robb F, Moore J, Winkler SAngela.  2023.  Hardware Requirements for 2D Cylindrical-High Pass Ladder Coil Design enabling Homogeneous Excitation in Ultra High-Field MRI. IEEE Symposium on Industrial Electronics & Applications (ISIEA).
Pendse M., Winkler SA, Rutt BK.  2014.  Flip Angle Inhomogeneity Constrained pTx Pulse Design for Minimum Peak Local SAR. Proc. Int. Soc. Magn. Res..
Winkler SA, Corea J.  2018.  First clinical pilot study using screen-printed flexible MRI receive coils for pediatric applications. Proc. Int. Soc. Magn. Res..
Motovilova E, Ching T, Vincent J, Shin J, Tan ETsoon, Taracila V, Robb FJL, Hashimoto M, Sneag DB, Winkler SAngela.  2022.  Fabrication Methods for Stretchable, Self-tuning Multi-element Liquid Metal Coil Arrays (LiquiTune). Gordon Research Conference. Invited late breaking, oral talk
Motovilova E, Ching T, Vincent J, Shin J, Tan ETsoon, Taracila V, Robb FJL, Hashimoto M, Sneag DB, Winkler SAngela.  2022.  Fabrication Methods for Stretchable, Self-tuning Multi-element Liquid Metal Coil Arrays (LiquiTune). ISMRM.
Gökyar S, Taracila V, Ballon DJ, Voss HU, Robb FJL, Winkler SA.  2021.  An Electrically Long Ultra-High Field MRI Volume Body Coil Design. Proc. 2021 ICEAA/IEEE APWC/USNC-URSI RSM.
Winkler SA, Picot P., Thornton M., Rutt BK.  2014.  Direct SAR Mapping by Thermoacoustic Imaging: A Feasibility Study. Proc. Int. Soc. Magn. Res..
Gökyar S, Voss HU, Taracila V, Robb FJL, Ballon DJ, Winkler SA.  2021.  A Comparative Study Highlighting a Novel UHF MRI Volume Body Coil Design. ISMRM Virtual Conference.
Lu J.Y, Grafendorfer T, Robb FJL, Winkler SA, Vasanawala S, Pauly J, Scott G.  2019.  Clock Transmission Methods for Wireless MRI: A Study on Clock Jitter & Impact on Data Sampling. Proc. Int. Soc. Magn. Res..